• Smoke Detector

    with Base Series
    The “SLR-835” series photoelectric smoke detectors come with the same features as that of
    the “SLR-835B” baseless series (listed above) with the exception th at it requires a matching
    base for installation. Please refer to website for available base styles to use with these
    detectors.

    Call for Price

    Smoke Detector

    Call for Price
  • Photoelectric Smoke Detector

    Direct Wire Series
    . Wide voltage range for use on either 12 or 24 volt systems
    . Low profile
    . 2 or 4 wire configuration
    . Direct wire installation- does not require a base
    . Highly stable operation, RF / transient protection (reduces false alarms)
    . Two built-in power / sensitivity supervision / alarm LED’ s (360˚ viewing)
    . Vandal resistant security locking feature
    . Removable smoke chamber for cleaning or replacement
    . Built-in automatic sensitivity check

    Call for Price
  • Phototelectric Smok Sensor ALN-V

    Photoelectric Smoke Sensor
    . Removable, High Performance Chamber
    . Twin fire LED’s allow 360° viewing
    . Locking mechanism (sensor to base)
    . Variable sensitivity
    . Electronically addressed
    .Pulsing/ non-pulsing controlled from panel

    Call for Price
  • Programming Cable X187

    Programming Cables
    . Cable Type: FireNET Family Programming
    . Cable Length: 10 feet (3 meters)
    . Left Connector: 10 Pin Serial (Female)
    . Right Connector: 9 Pin – DB9 (Female)
    . Non-Jacketed Version

    Call for Price

    Programming Cable X187

    Call for Price
  • Programming Cables S187

    Programming Cables
    . Cable Type: FireNET Family Programming
    . Cable Length: 10 feet (3 meters)
    . Left Connector: 10 Pin Serial (Female)
    . Right Connector: 9 Pin – DB9 (Female)
    . Jacketed Version

    Call for Price

    Programming Cables S187

    Call for Price
  • Selectable Ceiling Mount HC Series

    Selectable Ceiling Mount Strobe and Horn Strobe
    . Nominal Voltage 24 VDC
    . Tamperproof Field Selectable candela options of 15, 30, 75, 95,115 & 150
    . Synchronize HC Series by using Hochiki America Series Control Module
    . Input Terminals support 12 to 18 AWG
    . Switch Selection for High or Low dBA
    . Switch Selection for 2400Hz or Mechanical Tone
    . Switch Selection for Continuous or Temporal 3
    . Tamperproof Re-entrant Grill
    . Surface Mount with the HCSB (Hochiki Ceiling Surface Mount Box)
    . Silence Horn While Strobes Remain Flashing

    Call for Price
  • Single Input module

    a) Includes a single monitored input
    b) Small design for simple provision of a monitored input onto an ESP loop
    c) Flying leads for easy installation
    Call for Price

    Single Input module

    Call for Price
  • Single Output Module

    a) Includes a single monitored output
    b) Small design for simple provision of a monitored output onto an ESP loop
    c) Flying leads for easy installation
    d) Addressed with TCH-B100 Hand Held Programmer
    e) Approved by LPCB
    Call for Price

    Single Output Module

    Call for Price
  • SLR-24H

    Photoelectric/Heat Smoke Detector
    . 2 or 4 wire base compatibility, relay bases available
    . 135°F Fixed Temperature heat sensor (Latching)
    . Heat sensor protected by a built-in guard
    . Highly stable operation, RF/Transient protection
    . Low standby current, 45mA at 24VDC
    . Two built-in power/sensitivity supervision/alarm LED’s
    . Non-directional smoke chamber
    . Automatic Sensitivity window verification function meets outlined requirements in NFPA  72, Chapter 2 & 7, Inspection, Testing and Maintenance

    Call for Price

    SLR-24H

    Call for Price
  • Synchronization Control Module

    Synchronisation Control Module
    . Synchronize horn and strobe with the use of only two wires
    . Module is rated for 3 Amps continuous current and 5 Amps surge or inrush current
    . Synchronizes to 1Hz flash rate
    . Operates 1 “Class A” circuit or 2 “Class B” circuits at 3 Amps per circuit
    . Dual Synchronization Module only when using “Class B” circuits
    . A Green LED status indicator
    . Option to silence the horn while strobes continue to flash when using Temporal 3 Mode
    . HAVSM operates the HCS/HCC, HES3-24/HEC3-24, HES3-12/HEC3-12, HEC/HES/HEH, HSSPK Series and HX93 Series
    . HAVS module come with its own back box and cover plate

    Call for Price
  • Wallmount Speaker/Strobe

    Wall Mount Speaker/Strobe
    . Nominal Voltage 24 VDC
    . Tamperproof Field Selectable candela options of 15, 30, 75, 95 & 110
    . Synchronize HSSPKWLP Series by using Hochiki America HAVSM Synchronization Module
    . High Quality dBA Output
    . Frequency Range 400-4000Hz
    . Input Terminals supports 12 to 18 AWG
    . Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W, 2W and 4W
    . Field Selectable Speaker Voltage 25 or 70.7 VRMS Standard
    . Tamperproof Grill

    Call for Price

    Wallmount Speaker/Strobe

    Call for Price
  • Conventional Smoke Detector

    a) Removable, High Performance chamber
    b) Twin fire LEDs allow 360 degree viewing
    c) Supported by a range of barriers
    d) Remote indicator output
    e) ATEX certification to: II 1G EEx ia IIC T5 (Tamb=55 Degree C)
    f) Suitable for installation in areas at Category 1 (inc all lower categories)
    g) Approved by LPCB and GL