• Addressable SCI Manual Call Point HCP-E(HFP)-SCI

    a) Fast response
    b) Bi-coloured status LED (red for alarm, amber for short-circuit)
    c) Non-frangible element fitted as standard (conforms to EN54)
    d) Addressed with TCH-B100 Hand Held Programmer
    e) Surface or flush mounting
    f) LPCB Approved to EN54
    Call for Price
  • Analog Bases YBN-NSA-4

    Analogue Bases
    . UL & ULC Listed
    . Design for use with all NS DCP (digital communication protocol) analogue sensors
    . Contains a security locking tab for tamper protection
    . Available in 4 and 6 inch models

    Call for Price
  • Analogue Addressable Manual Pull Station DCP-AMS-KL

    Analogue Addressable Manual Pull Station
    . Addressable integrated design
    . All metal construction
    . Single and dual action models available
    . Extremely easy to operate
    . Bi-colored status LED indicates Standby and Alarm conditions
    . Address is programmable in EEPROM
    . Key lock or hex key lock models available
    . Terminals accept up to 14AWG wire
    . Surface mount back box available

    Call for Price
  • Analogue Addressable Manual Pull Station DCP-AMS-KL-LP

    Analogue Addressable Manual Pull Station
    . Addressable integrated design
    . All metal construction
    . Single and dual action models available
    . Extremely easy to operate
    . Bi-colored status LED indicates Standby and Alarm conditions
    . Address is programmable in EEPROM
    . Key lock or hex key lock models available
    . Terminals accept up to 14AWG wire
    . Surface mount back box available

    Call for Price
  • Analogue Base HSB-NSA-6

    Analogue Base
    . UL & ULC Listed
    . Design for use with all NS DCP (digital communication protocol) analogue sensors
    . Contains a security locking tab for tamper protection
    . Available in 4 and 6 inch models

    Call for Price
  • Analogue Dual Relay Controller CHQ-DRC2(HFP)

    a) Loop powered
    b) Single loop address
    c) 2 Independently controlled changeover relays
    d) Relays contact rated at 30 V dc at 1 A
    e) Auxiliary monitored input
    f) DIN-Rail version available
    g) Both models feature an integral short-circuit isolator
    h) Both models approved by LPCB
    Call for Price
  • Analogue Duct Detector DH-99 Series

    Analogue Duct Detector
    . Detects and limits the spread of smoke throughout building HVAC ducts
    . Compatible with building automation and fire alarm systems
    . Installs quickly and easily
    . No screens or filters to clean
    . Rugged gray steel back box with clear cover
    . Accessories – Remote LED alarm indication capability (DH-99-AR only)
    . Meets UL 268A Requirements

    Call for Price
  • Analogue Multi-Criteria Sensor ACC-V

    Analogue Multi-Criteria Sensor
    . User selectable modes
    . Incorporates Optical and Heat Chamber
    . Removable, High Performance Chamber
    . Twin fire LED’s allow 360° viewing
    . Pulsing/non-pulsing controlled from panel
    . Variable Sensitivity
    . Electronically addressed

    Call for Price
  • Analogue Sounder Base ASB

    Analogue Sounder Bases
    . Programmable evacuation codes – Continuous, March, ANSI Temporal patterns
    . Base learns the sensor address and assumes an upper range address (128-254)
    . Up to 127 sensors and 127 ASBs can be used on one SLC loop
    . Can be alarmed or reset by zone or by individual address
    . ASB SLC loop wire resistance = 50 ohms Max. (total SLC wire run length)
    . High sound pressure level (85dB SPL at 10 feet)

    Call for Price
  • Conventional Control Panel HCA

    Conventional Control Panel
    . UL864 9th Edition / NFPA Compliant
    . Fully programmable using simple menu options
    .Installer friendly and supports flush or surface mount without a separate trim-ring
    . Built-in two-line (16 Characters for each line) LCD display provides easy to read information
    . 15 Key control buttons for easy programming, reset and silencing.
    . Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display
    . 4 Programmable Supervised NAC outputs
    . 6.5 Amp power supply

    Call for Price
  • Conventional Duct Detectors HCP-1008

    Conventional Duct Detectors
    . Expandable panel selection
    . Class A or B initiating circuits
    . Indicating circuits with individual trouble indicators (1.7 Amp Max. per circuit)
    . Each indicating circuit can be silence-able or non-silenceable
    . Audibles may be configured as steady, temporal code, California code or march time
    . Each initiating circuit can be configured as alarm, supervisory, water-flow or trouble
    . Outputs for 4 wire re-settable smoke power supply
    . Alarm verification in initiating circuits
    . Easy configuration via DIP switches or push button and slide switches on front panel

    Call for Price
  • Conventional Smoke Detector SLR-E-IS(WHT)

    a) Removable, High Performance chamber
    b) Twin fire LEDs allow 360 degree viewing
    c) Supported by a range of barriers
    d) Remote indicator output
    e) ATEX certification to: II 1G EEx ia IIC T5 (Tamb=55 Degree C)
    f) Suitable for installation in areas at Category 1 (inc all lower categories)
    g) Approved by LPCB and GL
    Call for Price