• Single Input module

    a) Includes a single monitored input
    b) Small design for simple provision of a monitored input onto an ESP loop
    c) Flying leads for easy installation
    Call for Price

    Single Input module

    Call for Price
  • SLR-24H

    Photoelectric/Heat Smoke Detector
    . 2 or 4 wire base compatibility, relay bases available
    . 135°F Fixed Temperature heat sensor (Latching)
    . Heat sensor protected by a built-in guard
    . Highly stable operation, RF/Transient protection
    . Low standby current, 45mA at 24VDC
    . Two built-in power/sensitivity supervision/alarm LED’s
    . Non-directional smoke chamber
    . Automatic Sensitivity window verification function meets outlined requirements in NFPA  72, Chapter 2 & 7, Inspection, Testing and Maintenance

    Call for Price

    SLR-24H

    Call for Price
  • Photoelectric Smoke Detector

    Direct Wire Series
    . Wide voltage range for use on either 12 or 24 volt systems
    . Low profile
    . 2 or 4 wire configuration
    . Direct wire installation- does not require a base
    . Highly stable operation, RF / transient protection (reduces false alarms)
    . Two built-in power / sensitivity supervision / alarm LED’ s (360˚ viewing)
    . Vandal resistant security locking feature
    . Removable smoke chamber for cleaning or replacement
    . Built-in automatic sensitivity check

    Call for Price
  • Smoke Detector

    with Base Series
    The “SLR-835” series photoelectric smoke detectors come with the same features as that of
    the “SLR-835B” baseless series (listed above) with the exception th at it requires a matching
    base for installation. Please refer to website for available base styles to use with these
    detectors.

    Call for Price

    Smoke Detector

    Call for Price
  • Conventional Detectors HCP-1008

    Conventional Duct Detectors
    . Expandable panel selection
    . Class A or B initiating circuits
    . Indicating circuits with individual trouble indicators (1.7 Amp Max. per circuit)
    . Each indicating circuit can be silence-able or non-silenceable
    . Audibles may be configured as steady, temporal code, California code or march time
    . Each initiating circuit can be configured as alarm, supervisory, water-flow or trouble
    . Outputs for 4 wire re-settable smoke power supply
    . Alarm verification in initiating circuits
    . Easy configuration via DIP switches or push button and slide switches on front panel

    Call for Price
  • Intelligent Heat Sensor ATJ-EA

    Conventional Control Panel
    . UL864 9th Edition / NFPA Compliant
    . Fully programmable using simple menu options
    .Installer friendly and supports flush or surface mount without a separate trim-ring
    . Built-in two-line (16 Characters for each line) LCD display provides easy to read information
    . 15 Key control buttons for easy programming, reset and silencing.
    . Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display
    . 4 Programmable Supervised NAC outputs
    . 6.5 Amp power supply

    Call for Price
  • Signal Module WHE Series

    Weatherproof Evacuation Signals
    . Nominal voltage 24VDC
    . Unit is shipped with WHES24-75 Candela Strobe or WHEC24-75 Candela Horn/Strobe
    . Switch Selection for High dBA
    . Switch for Mechanical and 2400hz Tone
    . Switch for Continuous Tone
    . Input terminals supports 12 to 18 gauge wire
    . Tamperproof Re-entrant Grill
    . Wide Voltage Range of 16-33 VDC or FWR
    . Separate Horn and Strobe Functions
    . Synchronize Strobe and/or Horn by using HAVSM Module

    Call for Price

    Signal Module WHE Series

    Call for Price
  • Dual Input Monitor Module

    Dual Input Monitor Module
    . Capable of monitoring two separate circuits simultaneously
    . Mounts in standard 4” gang box
    . Each input can be programmed independently to monitor normally open or normally closed contacts

    Call for Price
  • Synchronization Control Module

    Synchronisation Control Module
    . Synchronize horn and strobe with the use of only two wires
    . Module is rated for 3 Amps continuous current and 5 Amps surge or inrush current
    . Synchronizes to 1Hz flash rate
    . Operates 1 “Class A” circuit or 2 “Class B” circuits at 3 Amps per circuit
    . Dual Synchronization Module only when using “Class B” circuits
    . A Green LED status indicator
    . Option to silence the horn while strobes continue to flash when using Temporal 3 Mode
    . HAVSM operates the HCS/HCC, HES3-24/HEC3-24, HES3-12/HEC3-12, HEC/HES/HEH, HSSPK Series and HX93 Series
    . HAVS module come with its own back box and cover plate

    Call for Price
  • HX93 Series

    Mini Horn
    . Nominal voltage 12VDC and 24VDC
    . Jumper for Selectable Temporal 3 or Continuous tone for HX93 Series
    . Horn Frequency of 3100Hz
    . Input terminals supports 12 to 18 gauge wire
    . Low Current Consumption
    . Textured Finish High Impact Plastic Faceplate
    . Available in Red or Off-White.

    Call for Price

    HX93 Series

    Call for Price
  • Selectable Ceiling Mount HC Series

    Selectable Ceiling Mount Strobe and Horn Strobe
    . Nominal Voltage 24 VDC
    . Tamperproof Field Selectable candela options of 15, 30, 75, 95,115 & 150
    . Synchronize HC Series by using Hochiki America Series Control Module
    . Input Terminals support 12 to 18 AWG
    . Switch Selection for High or Low dBA
    . Switch Selection for 2400Hz or Mechanical Tone
    . Switch Selection for Continuous or Temporal 3
    . Tamperproof Re-entrant Grill
    . Surface Mount with the HCSB (Hochiki Ceiling Surface Mount Box)
    . Silence Horn While Strobes Remain Flashing

    Call for Price