Analogue DCP-AMS-KL
Analogue Addressable Manual Pull Station
. Addressable integrated design
. All metal construction
. Single and dual action models available
. Extremely easy to operate
. Bi-colored status LED indicates Standby and Alarm conditions
. Address is programmable in EEPROM
. Key lock or hex key lock models available
. Terminals accept up to 14AWG wire
. Surface mount back box availableCall for PriceAnalogue DCP-AMS-KL
Call for Price -
Analogue DCP-AMS-KL-LP
Analogue Addressable Manual Pull Station
. Addressable integrated design
. All metal construction
. Single and dual action models available
. Extremely easy to operate
. Bi-colored status LED indicates Standby and Alarm conditions
. Address is programmable in EEPROM
. Key lock or hex key lock models available
. Terminals accept up to 14AWG wire
. Surface mount back box availableCall for PriceAnalogue DCP-AMS-KL-LP
Call for Price -
Analogue Duct Detector
Analogue Duct Detector
. Detects and limits the spread of smoke throughout building HVAC ducts
. Compatible with building automation and fire alarm systems
. Installs quickly and easily
. No screens or filters to clean
. Rugged gray steel back box with clear cover
. Accessories – Remote LED alarm indication capability (DH-99-AR only)
. Meets UL 268A RequirementsCall for PriceAnalogue Duct Detector
Call for Price -
Wallmount Speaker/Strobe
Wall Mount Speaker/Strobe
. Nominal Voltage 24 VDC
. Tamperproof Field Selectable candela options of 15, 30, 75, 95 & 110
. Synchronize HSSPKWLP Series by using Hochiki America HAVSM Synchronization Module
. High Quality dBA Output
. Frequency Range 400-4000Hz
. Input Terminals supports 12 to 18 AWG
. Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W, 2W and 4W
. Field Selectable Speaker Voltage 25 or 70.7 VRMS Standard
. Tamperproof GrillCall for PriceWallmount Speaker/Strobe
Call for Price -
Selectable Ceiling Mount HC Series
Selectable Ceiling Mount Strobe and Horn Strobe
. Nominal Voltage 24 VDC
. Tamperproof Field Selectable candela options of 15, 30, 75, 95,115 & 150
. Synchronize HC Series by using Hochiki America Series Control Module
. Input Terminals support 12 to 18 AWG
. Switch Selection for High or Low dBA
. Switch Selection for 2400Hz or Mechanical Tone
. Switch Selection for Continuous or Temporal 3
. Tamperproof Re-entrant Grill
. Surface Mount with the HCSB (Hochiki Ceiling Surface Mount Box)
. Silence Horn While Strobes Remain FlashingCall for PriceSelectable Ceiling Mount HC Series
Call for Price -
Dual Input Monitor Module
Dual Input Monitor Module
. Capable of monitoring two separate circuits simultaneously
. Mounts in standard 4” gang box
. Each input can be programmed independently to monitor normally open or normally closed contactsCall for PriceDual Input Monitor Module
Call for Price -
Signal Module WHE Series
Weatherproof Evacuation Signals
. Nominal voltage 24VDC
. Unit is shipped with WHES24-75 Candela Strobe or WHEC24-75 Candela Horn/Strobe
. Switch Selection for High dBA
. Switch for Mechanical and 2400hz Tone
. Switch for Continuous Tone
. Input terminals supports 12 to 18 gauge wire
. Tamperproof Re-entrant Grill
. Wide Voltage Range of 16-33 VDC or FWR
. Separate Horn and Strobe Functions
. Synchronize Strobe and/or Horn by using HAVSM ModuleCall for PriceSignal Module WHE Series
Call for Price -
Intelligent Heat Sensor ATJ-EA
Conventional Control Panel
. UL864 9th Edition / NFPA Compliant
. Fully programmable using simple menu options
.Installer friendly and supports flush or surface mount without a separate trim-ring
. Built-in two-line (16 Characters for each line) LCD display provides easy to read information
. 15 Key control buttons for easy programming, reset and silencing.
. Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display
. 4 Programmable Supervised NAC outputs
. 6.5 Amp power supplyCall for PriceIntelligent Heat Sensor ATJ-EA
Call for Price -
Conventional Detectors HCP-1008
Conventional Duct Detectors
. Expandable panel selection
. Class A or B initiating circuits
. Indicating circuits with individual trouble indicators (1.7 Amp Max. per circuit)
. Each indicating circuit can be silence-able or non-silenceable
. Audibles may be configured as steady, temporal code, California code or march time
. Each initiating circuit can be configured as alarm, supervisory, water-flow or trouble
. Outputs for 4 wire re-settable smoke power supply
. Alarm verification in initiating circuits
. Easy configuration via DIP switches or push button and slide switches on front panelCall for PriceConventional Detectors HCP-1008
Call for Price -
Smoke Detector
with Base Series
The “SLR-835” series photoelectric smoke detectors come with the same features as that of
the “SLR-835B” baseless series (listed above) with the exception th at it requires a matching
base for installation. Please refer to website for available base styles to use with these
detectors.Call for PriceSmoke Detector
Call for Price -
Photoelectric Smoke Detector
Direct Wire Series
. Wide voltage range for use on either 12 or 24 volt systems
. Low profile
. 2 or 4 wire configuration
. Direct wire installation- does not require a base
. Highly stable operation, RF / transient protection (reduces false alarms)
. Two built-in power / sensitivity supervision / alarm LED’ s (360˚ viewing)
. Vandal resistant security locking feature
. Removable smoke chamber for cleaning or replacement
. Built-in automatic sensitivity checkCall for PricePhotoelectric Smoke Detector